0 reviews | UPC: 645759359858 | Model: Fotric 226B
Thermal Imaging System to Automatically Screen for Elevated Body Temperature - Rapid Scanning for High Traffic Areas
Your Price: $4,499.00
Sign-in for EDU Pricing!
We accept purchase orders and all major credit cards. We also provide financing via Klarna at checkout for qualifying purchases.
Have a question or need to apply for payment terms?
Contact us.
(0)
In Stock!
The Fotric 226B is an intelligent thermographic monitoring system. The 226B offers a very efficient and streamlined solution for detection of elevated or abnormal body temperature. It is designed to simplify the task of temperature monitoring and identifying subjects displaying abnormal readings. Please note, the Fotric 226B is not medical equipment and can only be used to measure temperature. The 226B cannot be used to diagnose COVID-19/Coronavirus. Scan individuals while keeping lines moving The Fotric 226B features a powerful AI facial detection module and is able to automatically detect and screen individuals as they pass through its field of view. With a detection range of 2.6 to 10.5 feet, personnel are able to obtain accurate readings while adhering to social distancing requirements. The 226B can be placed at the head of a queue and will alert personnel when its temperature alarm has been triggered. While the 226B is capable of scanning multiple people simultaneously, recent guidelines from the US Food and Drug Administration recommend scanning one person at a time. It is very easy to adhere to these suggestions with the 226B. With a properly configured line, testing subjects can face the camera directly while having their temperature read, and can do so without stopping. This keeps the line moving and helps to reduce congestion. FDA best practices also include the removal of any facial obstruction (hat, glasses, mask, scarf), hair pulled away from the face, and clean/dry skin.
Intelligent temperature calibration algorithm The WLIR has a built-in body temperature calibration algorithm. This automatically collects facial temperatures from different scenarios for self-learning and adjusts the alarm threshold in real time by adapting to changes in ambient temperature. This also helps prevent false positives from fluctuations in morning and evening temperature.
Automatic statistics on screening and alarm numbers The WLIR software can automatically count the number of screened personnel and suspected abnormal body temperature alarms.
Automatic temperature alarm When a person exhibiting abnormal temperature is detected, an audio alert will sound and the facial recognition frame will immediately turn red. This provides personnel a fast method for identification.
Automatic snapshot when abnormal body temperature is detected When an alarm is triggered, the unit will automatically capture a photo of the detected person for later statistics and analysis.
The Fotric 226B is compatible with the 462 blackbody calibrator. The 462 is mounted in the field of view along with testing subjects and generates a known, constant temperature. By having a reference temperature in the field of view, the 226B is able to provide measurements with greater accuracy than it would have without the blackbody.
NOTE REGARDING FDA APPROVAL: The FDA has recently issued guidance providing that it does not object to the distribution and use of telethermographic systems intended for adjunctive diagnostic/initial body temperature assessment and screening during the COVD-19 pandemic where such devices do not create an undue risk. For more information, see https://www.fda.gov/medical-devices/general-hospital-devices-and-supplies/thermal-imaging-systems-infrared-thermographic-systems-thermal-imaging-cameras and https://www.fda.gov/medical-devices/emergency-situations-medical-devices/non-contact-temperature-assessment-devices-during-covid-19-pandemic. We obviously cannot now predict how long the COVID-19 pandemic will last, or what position the FDA may take on such devices in the future. You should always follow all instructions and rules when using any telethermographic system, such as those sold by TEquipment, and should consult with your attorney concerning relevant legal requirements and best practices for implementation and COVID-19 screening.”
Is there an annual fee for the software?
Answers (1) - Asked by Anonymous
I have this question too (10)
No.
I found this helpful (2)
Inaccurate? (0)
Answered by TEquipment
Why does it not detect any faces?
I have this question too (38)
The face detection rate of the software cannot always be completely accurate. It is necessary to pay attention to these situations in which faces may not be successfully detected: People with black masks; People with long hair covering their foreheads; People with hats; People with less hair; People walking too fast, Etc. Additionally, misidentification may occur where other objects are mistakenly considered as human faces for temperature measurement.
I found this helpful (1)
Inaccurate? (1)
How to shutdown?
I have this question too (8)
To manually shut down, press and hold the power button for about 6 seconds. If the device is disconnected from the software (software has been closed or the computer is in sleep mode), it will automatically shut down after 5 minutes.
What is live detection?
I have this question too (11)
Live detection is a new feature that can verify if the measured object is a real living body, which can exclude the effects of photos, videos, screen recordings, etc. Please note that this function will be continuously upgraded and may have a certain error rate.
I found this helpful (0)
The Windows 8-/-10 version of the driver cannot install successfully?
I have this question too (20)
Please check whether the driver signature enforcement is disabled (disable driver signature enforcement) . If this step is not performed ,the prompt below will appear. The second possibility is that a 32-bit driver (x86) or a 64-bit driver (x64) is installed on a 64-bit or 32-bit system, respectively.
Why can it not display infrared thermal image?
I have this question too (16)
First, please make sure that the device 226B is powered on, and the status light is green. Second, make sure that the device driver is installed correctly. Third, make sure the USB connection between the device and the computer is stable.
Why can it not display visible light image?
I have this question too (7)
There may be several reasons as to why the software prompts that the visible light (DC) image connection fails: 1. The USB cable connection of the visible light camera is faulty. Please reconnect or try again with a different USB port on the computer; 2. The computer may not have a camera driver installed. Please go online (Logitech official website: https://www.logitech.com) to, download and install the relevant driver. 3. Please check if the network is disabled. Disabling the network may cause the visible light image to fail.
How to activate Face detection?
I have this question too (12)
This function needs to be activated online for first-time use and then the network connection is no longer needed. Please note that: the network can be disconnected after activation, but do not disable the network, If disabled the software will prompt that it cannot connect to the visible light camera and the face detection function will need to be activated again. Please also make sure that the computer time is consistent with the local time.
How does distance affect temperature measurement?
First, we recommend that the location of the temperature measurement point is fixed, as well as the distance from the device to the measurement point. Then the device is focused and matched under this premise. Therefore, when the person to be inspected reaches the temperature measurement point, the focal length is appropriate, and the measured temperature is accurate. If the person being inspected continues to walk towards the IR imaging camera, the focal length of the infrared image changes, and the measured temperature may increase. Therefore, when the FOTRIC 226B equipment is installed, we recommend that the temperature measurement route arranged in an "L" shape. After reaching the determined temperature measurement point, the channel turns left or right by 90°.
Why is there no alarm when temperature exceeds 45 degree celcius?
When the measured temperature of the human face exceeds 45 °C, the software will not emit an alarm. The software’s upper limit of the alarm temperature is 45 °C. If the temperature of the human body exceeds 45 ° C, the person would feel unmistakably ill and should go to the hospital for treatment immediately. If the person keeps appearing in some places, he or she may use many methods to reduce his or her face temperature to prevent being detected by infrared thermal imaging devices.
How to use HawkAI mode data sampling?
I have this question too (6)
When using AI mode, the software will prompt: "You have to resample temperature for 10 sets". We recommend sampling the temperature of 10 different people with variations, so that the temperature compensation value of the AI algorithm can fit most people.
What is HawkAI Mode?
I have this question too (9)
The working principle of the HawkAI mode is that the FOTRIC 226B first collects the human body surface (face) temperature, and then automatically calculates the compensation temperature through the AI algorithm. This converts the human body surface temperature into the real body temperature. HawkAI mode can adjust the compensation temperature value in real time according to the flow of people continuously passing the temperature measurement point, adapt to the change of ambient temperature. Please note that: the AI mode is designed with caution. The goal is to screen out people with a high body temperature in the crowd, and then perform a second temperature measurement. Body temperature varies from person to person. The biggest difference can be as high as 1-2 °C. With careful consideration, please have the screened person to stabilize for 5-10 minutes, and then perform a second temperature measurement. If their temperature is still high, it is recommended to use a medical thermometer to repeat the measurement.
What is Threshold mode?
I have this question too (5)
The threshold mode directly displays the human body surface (face) temperature is greatly affected by the environment. In threshold mode, the temperature compensation can be performed manually, and the compensation temperature value is =10 ° C.
How to match visible and infrared images?
To use the device correctly, the visible and infrared images must be matched. The visible light detection frame (right) is positioned to the face, while the infrared detection frame (left) does not match the face position. The temperature test result is incorrect, as it has not read a human face temperature. After matching, the face detection frame of the infrared photo and the visible light photo are in the same position, so the measured result is accurate.
Inaccurate temperature on blurry images?
The FOTRIC 226B uses manual focus adjustment, and can only correctly measure temperature if its focus is accurate. If the focus is not accurate, the infrared image can be blurred, and the corresponding measured temperature can also result in a large error.
Backlighting problem? Cannot detect human face?
The recommended installation environment for the FOTRIC 226B is indoors with good lighting. Try to avoid a backlit environment, which can affect the accuracy of face detection or even result in detection failure. When the device is facing a door or window, the facial detection failure in the figure below may occur. It is recommended to change the orientation of the device or turn on the indoor lights to reduce the effect of backlighting.